Kikusui TOS9303LC AC/DC Hipot Tester with Insulation Resistance, Ground Bond and Leakage Current Test Rental

£348.00 (£417.60 inc. VAT)

Prices shown are weekly rental rates.

You will be charged weekly until the items are returned

Available on back-order

Compare with other AC/DC Flash Testers

SKUImageBrandProduct NameStockPrice
TOS9303LC-RentalImage of Telonic tos9303lc frontkikusuiKikusui TOS9303LC AC/DC Hipot Tester with Insulation Resistance, Ground Bond and Leakage Current Test RentalOn Backorder£348.00
TOS5301Image of Tos5301kikusuiDiscontinued: Kikusui TOS5301 AC/DC Flash Tester / Hipot Tester 0-5kV(AC) 0-6kV(DC) AC 0-100mA (200mA S/C)/ DC 0-10mAOn Backorder£2,099.00
TOS5200Image of Kikusui tos5200 5kv ac hipot tester front1 pngkikusuiKikusui TOS5200 AC Flash Tester / HiPot Tester 0-5000V 0-100mA (200mA S/C)On Backorder£1,203.00
TOS5401Image of Kikusui tos5402 high quality photo telonicukkikusuiKikusui TOS5401 5kV AC / 6kV DC Hipot Withstanding Voltage TesterOn Backorder£2,625.00
TOS5402Image of Kikusui tos5402 high quality photo telonicukkikusuiKikusui TOS5402 5kV AC Hipot and 10GΩ Insulation Resistance TesterOn Backorder£2,625.00
TOS5403Image of Kikusui tos5402 high quality photo telonicukkikusuiKikusui TOS5403 6kV DC Hipot and 10GΩ Insulation Resistance TesterLow stock1£2,625.00
TOS9300Image of Telonic tos9300 frontkikusuiKikusui TOS9300 AC HiPot Tester with Insulation Resistance TestOn Backorder£3,492.00
TOS9301Image of Telonic tos9301 frontkikusuiKikusui TOS9301 AC/DC HiPot Tester with Insulation Resistance Test3£4,192.00
TOS9301PDImage of Telonic tos9301 frontkikusuiKikusui TOS9301PD AC/DC HiPot Tester with Insulation Resistance and Partial Discharge TestOn Backorder£8,645.00
TOS9302Image of Telonic tos9302 frontkikusuiKikusui TOS9302 AC HiPot Tester with Ground Bond TestOn Backorder£4,586.00
TOS9303Image of Telonic tos9303 frontkikusuiKikusui TOS9303 AC/DC HiPot Tester with Insulation Resistance and Ground Bond TestLow stock2£5,289.00
TOS9303LCImage of Telonic tos9303lc frontkikusuiKikusui TOS9303LC AC/DC Hipot Tester with Insulation Resistance, Ground Bond and Leakage Current TestOn Backorder£7,254.00
TOS9311Image of Kikusui tos9311 telonic ukkikusuiKikusui TOS9311 10kV AC/DC HiPot Tester / Insulation Resistance TesterOn Backorder£7,092.00
MICROTEST-7640Image of Microtest 7640 final telonicukmicrotestMICROTEST 7640 1-Channel 5kV AC / 6kV DC / 100GΩ Hi-Pot TesterOn BackorderCall us
MICROTEST-7641Image of Microtest 7641 final telonicukmicrotestMICROTEST 7641 8-Channel 5kV AC / 6kV DC / 100GΩ Hi-Pot TesterOn BackorderCall us
TOS5301-RentalImage of Tos5301kikusuiRental Kikusui TOS5301 AC/DC Flash Tester / Hipot Tester 0-5kV(AC) 0-6kV(DC) AC 0-100mA (200mA S/C)/ DC 0-10mALow stock2£118.00
TOS5302-RentalImage of Tos5302 frontkikusuiRental Kikusui TOS5302 AC Flash Tester / HiPot plus Insulation Resistance Tester 0-5kV(AC) 25-1000V(IR) AC 0-100mA (200mA S/C)Low stock1£140.00
TOS9303-RentalImage of Telonic tos9303 frontkikusuiRental Kikusui TOS9303 AC/DC HiPot Tester with Insulation Resistance and Ground Bond TestOn Backorder£293.00
TOS9301PD- DemoImage of Telonic tos9301 frontkikusuiRental: Kikusui TOS9301PD AC/DC HiPot Tester with Insulation Resistance and Partial Discharge TestLow stock1£348.00
TOS9311 - DemoImage of Kikusui tos9311 telonic ukkikusuiRental: Kikusui TOS9311 10kV AC/DC HiPot Tester / Insulation Resistance TesterLow stock1£348.00

Description

Kikusui TOS9303LC Safety Tester Rental

The TOS9300 Series is a high performance electrical safety analyser that complies to a wide range of universal standards. HiPot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests. The TOS9300 Series is a high performance electrical safety analyser that complies to a wide range of universal standards. HiPot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.

 

Additional information

Documents

Kikusui TOS9300

TOS9300 Specifications
Model TOS9300 TOS9301 TOS9302 TOS9303 TOS9303LC
Output Function
AC Output Section
Output range 0.050 kV to 5.000 kV 0.050 kV to 5.000 kV 0.050 kV to 5.000 kV 0.050 kV to 5.000 kV 0.050 kV to 5.000 kV
Resolution 1 V 1 V 1 V 1 V 1 V
Setting accuracy ±(1.2 % of setting + 20 V) (at no load) ±(1.2 % of setting + 20 V) (at no load) ±(1.2 % of setting + 20 V) (at no load) ±(1.2 % of setting + 20 V) (at no load) ±(1.2 % of setting + 20 V) (at no load)
Max. rated load 500 VA(5 kV / 100 mA) 500 VA(5 kV / 100 mA) 500 VA(5 kV / 100 mA) 500 VA(5 kV / 100 mA) 500 VA(5 kV / 100 mA)
Max. rated current 100 mA (when the output voltage is 0.2 kV or higher) 100 mA (when the output voltage is 0.2 kV or higher) 100 mA (when the output voltage is 0.2 kV or higher) 100 mA (when the output voltage is 0.2 kV or higher) 100 mA (when the output voltage is 0.2 kV or higher)
Transformer rating 500 VA 500 VA 500 VA 500 VA 500 VA
Output voltage waveform Sine Sine Sine Sine Sine
Distortion 2 % or less. (when the output voltage is 0.5 kV or higher and no load or a pure resistive load is connected) 2 % or less. (when the output voltage is 0.5 kV or higher and no load or a pure resistive load is connected) 2 % or less. (when the output voltage is 0.5 kV or higher and no load or a pure resistive load is connected) 2 % or less. (when the output voltage is 0.5 kV or higher and no load or a pure resistive load is connected) 2 % or less. (when the output voltage is 0.5 kV or higher and no load or a pure resistive load is connected)
Crest factor √2 ± 3 % (800 V or more) √2 ± 3 % (800 V or more) √2 ± 3 % (800 V or more) √2 ± 3 % (800 V or more) √2 ± 3 % (800 V or more)
Frequency 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz 50 Hz / 60 Hz
Accuracy ±0.1 % ±0.1 % ±0.1 % ±0.1 % ±0.1 %
Voltage regulation ±3 % or less (when changing from maximum rated load to no load) ±3 % or less (when changing from maximum rated load to no load) ±3 % or less (when changing from maximum rated load to no load) ±3 % or less (when changing from maximum rated load to no load) ±3 % or less (when changing from maximum rated load to no load)
Short-circuit current 200 mA or more (output voltage 0.5 kV or higher) 200 mA or more (output voltage 0.5 kV or higher) 200 mA or more (output voltage 0.5 kV or higher) 200 mA or more (output voltage 0.5 kV or higher) 200 mA or more (output voltage 0.5 kV or higher)
Output method PWM switching PWM switching PWM switching PWM switching PWM switching
Start voltage The voltage at the start of the test can be set. The voltage at the start of the test can be set. The voltage at the start of the test can be set. The voltage at the start of the test can be set. The voltage at the start of the test can be set.
Setting range 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage
Resolution 1 % 1 % 1 % 1 % 1 %
Output voltage monitor function If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated.
DC Output Function
DC Output Section
Output voltage range 0.050 kV to 7.200 kV 0.050 kV to 7.200 kV 0.050 kV to 7.200 kV 0.050 kV to 7.200 kV 0.050 kV to 7.200 kV
Resolution 1 V 1 V 1 V 1 V 1 V
Setting accuracy ±(1.2 % of setting + 20 V) ±(1.2 % of setting + 20 V) ±(1.2 % of setting + 20 V) ±(1.2 % of setting + 20 V) ±(1.2 % of setting + 20 V)
Max. rated load 100 W (5 kV/20 mA, 7.2 kV/13.9 mA) 100 W (5 kV/20 mA, 7.2 kV/13.9 mA) 100 W (5 kV/20 mA, 7.2 kV/13.9 mA) 100 W (5 kV/20 mA, 7.2 kV/13.9 mA) 100 W (5 kV/20 mA, 7.2 kV/13.9 mA)
Max. rated current 20 mA 20 mA 20 mA 20 mA 20 mA
Ripple
7.2 kV no load 20 Vp-p (TYP) 20 Vp-p (TYP) 20 Vp-p (TYP) 20 Vp-p (TYP) 20 Vp-p (TYP)
Max. rated load 50 Vp-p (TYP) 50 Vp-p (TYP) 50 Vp-p (TYP) 50 Vp-p (TYP) 50 Vp-p (TYP)
Voltage regulation 1 % or less (when changing from maximum rated load to no load) 1 % or less (when changing from maximum rated load to no load) 1 % or less (when changing from maximum rated load to no load) 1 % or less (when changing from maximum rated load to no load) 1 % or less (when changing from maximum rated load to no load)
Short-circuit current 100 mA (TYP) (200 mA peak) 100 mA (TYP) (200 mA peak) 100 mA (TYP) (200 mA peak) 100 mA (TYP) (200 mA peak) 100 mA (TYP) (200 mA peak)
Discharge function Forced discharge after test completion (discharge resistance: 125 kΩ) Forced discharge after test completion (discharge resistance: 125 kΩ) Forced discharge after test completion (discharge resistance: 125 kΩ) Forced discharge after test completion (discharge resistance: 125 kΩ) Forced discharge after test completion (discharge resistance: 125 kΩ)
Start voltage The voltage at the start of the test can be set. The voltage at the start of the test can be set. The voltage at the start of the test can be set. The voltage at the start of the test can be set. The voltage at the start of the test can be set.
Setting range 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage 0 % to 99 % of the test voltage
Resolution 1 % 1 % 1 % 1 % 1 %
Output voltage monitor function If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated. If the output voltage exceeds ±(10 % of setting + 50 V), the output is turned off, and the protection function is activated.
Measurement Function
Voltmeter
Measurement range 0.00 kV to 7.50 kV AC/DC 0.00 kV to 7.50 kV AC/DC 0.00 kV to 7.50 kV AC/DC 0.00 kV to 7.50 kV AC/DC 0.00 kV to 7.50 kV AC/DC
Resolution 0.1 V 0.1 V 0.1 V 0.1 V 0.1 V
Accuracy ±(1.2 % of reading + 5 V) ±(1.2 % of reading + 5 V) ±(1.2 % of reading + 5 V) ±(1.2 % of reading + 5 V) ±(1.2 % of reading + 5 V)
Response Can be switched between true rms and mean-value response rms conversion.
Peak-value response in a separate system
(the peak-value response is for measuring the dielectric breakdown voltage while rising)
Can be switched between true rms and mean-value response rms conversion.
Peak-value response in a separate system
(the peak-value response is for measuring the dielectric breakdown voltage while rising)
Can be switched between true rms and mean-value response rms conversion.
Peak-value response in a separate system
(the peak-value response is for measuring the dielectric breakdown voltage while rising)
Can be switched between true rms and mean-value response rms conversion.
Peak-value response in a separate system
(the peak-value response is for measuring the dielectric breakdown voltage while rising)
Can be switched between true rms and mean-value response rms conversion.
Peak-value response in a separate system
(the peak-value response is for measuring the dielectric breakdown voltage while rising)
Hold function The voltage measurement after a test is finished is held while the pass/fail judgment is displayed The voltage measurement after a test is finished is held while the pass/fail judgment is displayed The voltage measurement after a test is finished is held while the pass/fail judgment is displayed The voltage measurement after a test is finished is held while the pass/fail judgment is displayed The voltage measurement after a test is finished is held while the pass/fail judgment is displayed
Ammeter
Measurement range AC: 0.00 mA to 110 mA, DC: 0.00 mA to 22 mA (Current including the active component and reactive component) AC: 0.00 mA to 110 mA, DC: 0.00 mA to 22 mA (Current including the active component and reactive component) AC: 0.00 mA to 110 mA, DC: 0.00 mA to 22 mA (Current including the active component and reactive component) AC: 0.00 mA to 110 mA, DC: 0.00 mA to 22 mA (Current including the active component and reactive component) AC: 0.00 mA to 110 mA, DC: 0.00 mA to 22 mA (Current including the active component and reactive component)
Accuracy ±(1 % of reading + 2 μA) (active component) ±(1 % of reading + 2 μA) (active component) ±(1 % of reading + 2 μA) (active component) ±(1 % of reading + 2 μA) (active component) ±(1 % of reading + 2 μA) (active component)
Response Can be switched between true rms and mean-value response rms conversion. Can be switched between true rms and mean-value response rms conversion. Can be switched between true rms and mean-value response rms conversion. Can be switched between true rms and mean-value response rms conversion. Can be switched between true rms and mean-value response rms conversion.
Hold function The current measurement after a test is finished is held while the pass judgment is displayed The current measurement after a test is finished is held while the pass judgment is displayed The current measurement after a test is finished is held while the pass judgment is displayed The current measurement after a test is finished is held while the pass judgment is displayed The current measurement after a test is finished is held while the pass judgment is displayed
Offset cancel function Cancels up to 10 mA of the current flowing through the insulation resistance and stray capacitance components across
output cables and the like (resistance component only for DC tests). OFF function available.
Cancels up to 10 mA of the current flowing through the insulation resistance and stray capacitance components across
output cables and the like (resistance component only for DC tests). OFF function available.
Cancels up to 10 mA of the current flowing through the insulation resistance and stray capacitance components across
output cables and the like (resistance component only for DC tests). OFF function available.
Cancels up to 10 mA of the current flowing through the insulation resistance and stray capacitance components across
output cables and the like (resistance component only for DC tests). OFF function available.
Cancels up to 10 mA of the current flowing through the insulation resistance and stray capacitance components across
output cables and the like (resistance component only for DC tests). OFF function available.
Calibration Active component: Calibrated with the rms of a sine wave using a pure resistive load.
Reactive component: Not calibrated.
Active component: Calibrated with the rms of a sine wave using a pure resistive load.
Reactive component: Not calibrated.
Active component: Calibrated with the rms of a sine wave using a pure resistive load.
Reactive component: Not calibrated.
Active component: Calibrated with the rms of a sine wave using a pure resistive load.
Reactive component: Not calibrated.
Active component: Calibrated with the rms of a sine wave using a pure resistive load.
Reactive component: Not calibrated.

Note* Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.