| Measurement method |
2-wire |
2-wire |
2-wire |
| Available test points |
128 / 256 / 512 |
128 / 256 / 512 |
128 / 256 / 512 |
| AC Hipot voltage |
Not available |
100–700 V |
100–1,000 V |
| DC Hipot voltage |
50–1,000 V |
50–1,000 V |
50–1,500 V |
| AC Hipot leakage current |
Not available |
0.01–5 mA |
0.01–5 mA |
| AC arc detection settings |
Not available |
1–8 |
1–8 |
| DC Hipot leakage current |
0.1–1,000 µA |
0.1–1,000 µA |
0.1–1,000 µA |
| DC arc detection settings |
1–8 |
1–8 |
1–8 |
| Insulation resistance |
0.1 MΩ–1 GΩ |
0.1 MΩ–1 GΩ |
0.1 MΩ–1 GΩ |
| Hipot output accuracy |
±5% |
±5% |
±5% |
| Hipot measurement basic accuracy |
±5% |
±5% |
±5% |
| Rated output (manufacturer description) |
5 V DC |
5 V DC |
5 V DC |
| Hipot measurement time |
0.01–60 s |
0.01–60 s |
0.01–60 s |
| Maximum allowable DUT capacitance |
5 µF |
5 µF |
5 µF |
| Continuity resistance |
100 mΩ–52 Ω |
100 mΩ–52 Ω |
100 mΩ–52 Ω |
| Continuity test current |
35 mA |
35 mA |
35 mA |
| Intermittent continuity |
20 Ω–2 kΩ |
20 Ω–2 kΩ |
20 Ω–2 kΩ |
| O/S, intermittent O/S and quick intermittent open circuit |
1–100 kΩ |
1–100 kΩ |
1–100 kΩ |
| Single-side testing and O/S terminal judgement |
Supported |
Supported |
Supported |
| Component resistance |
100 mΩ–2 MΩ |
100 mΩ–2 MΩ |
100 mΩ–2 MΩ |
| Resistance signal |
2.4 V fixed |
2.4 V fixed |
2.4 V fixed |
| Component capacitance |
10 pF–3 µF |
10 pF–3 µF |
10 pF–3 µF |
| Capacitance signal |
1.2 V fixed |
1.2 V fixed |
1.2 V fixed |
| Capacitance frequency |
AUTO |
AUTO |
AUTO |
| Diode voltage |
0.1–6.8 V |
0.1–6.8 V |
0.1–6.8 V |
| Test files |
Up to 500 |
Up to 500 |
Up to 500 |
| Display |
320 × 240 dot-matrix |
320 × 240 dot-matrix |
320 × 240 dot-matrix |
| Advanced functions |
Programmable continuous testing / pin search / self-diagnosis |
Programmable continuous testing / pin search / self-diagnosis |
Programmable continuous testing / pin search / self-diagnosis |
| Scan modes |
Automatic / manual / external trigger |
Automatic / manual / external trigger |
Automatic / manual / external trigger |
| Controls |
System / Rapid / Edit / Function |
System / Rapid / Edit / Function |
System / Rapid / Edit / Function |
| Indication |
Pass/Fail and HV indicators / screen / sound |
Pass/Fail and HV indicators / screen / sound |
Pass/Fail and HV indicators / screen / sound |
| Operation |
Manual / automatic / remote |
Manual / automatic / remote |
Manual / automatic / remote |
| Interfaces |
RS-232 / USB Host / Print / Remote |
RS-232 / USB Host / Print / Remote |
RS-232 / USB Host / Print / Remote |
| PC Link |
Supported; software is an optional ordering item |
Supported; software is an optional ordering item |
Supported; software is an optional ordering item |
| Supply |
115 / 230 V AC ±10%, 50 / 60 Hz |
115 / 230 V AC ±10%, 50 / 60 Hz |
115 / 230 V AC ±10%, 50 / 60 Hz |
| Operating environment |
15–35°C; ≤70% RH |
15–35°C; ≤70% RH |
15–35°C; ≤70% RH |
| Dimensions W × H × D |
128P: 435 × 145 × 406 mm; 256P: 435 × 145 × 406 mm; 512P: 435 × 190 × 406 mm |
128P: 435 × 145 × 406 mm; 256P: 435 × 145 × 406 mm; 512P: 435 × 190 × 406 mm |
128P: 435 × 145 × 406 mm; 256P: 435 × 145 × 406 mm; 512P: 435 × 190 × 406 mm |
| Weight |
128P: 8.44 kg; 256P: 9.3 kg; 512P: 14 kg |
128P: 8.44 kg; 256P: 9.3 kg; 512P: 14 kg |
128P: 8.44 kg; 256P: 9.3 kg; 512P: 14 kg |
| Power consumption |
128P: 70 VA; 256P: 100 VA; 512P: 150 VA |
128P: 70 VA; 256P: 100 VA; 512P: 150 VA |
128P: 70 VA; 256P: 100 VA; 512P: 150 VA |
| Voltage qualification |
Manufacturer note: at a 5 MΩ setting or below 5 µA, maximum test voltage is 650 V; AC tolerance setting range 0.01–5 mA. Consult the manual for the test conditions. |
Manufacturer note: at a 5 MΩ setting or below 5 µA, maximum test voltage is 650 V; AC tolerance setting range 0.01–5 mA. Consult the manual for the test conditions. |
Manufacturer note: at a 5 MΩ setting or below 5 µA, maximum test voltage is 650 V; AC tolerance setting range 0.01–5 mA. Consult the manual for the test conditions. |
| Additional test qualifications |
Correct/zero before AC Hipot measurements below 0.1 mA; follow the manual for insulation measurements. |
Correct/zero before AC Hipot measurements below 0.1 mA; follow the manual for insulation measurements. |
Correct/zero before AC Hipot measurements below 0.1 mA; follow the manual for insulation measurements. |
Reviews